We (@redford, @mrtick and I) have reverse engineered the PLC code of NEWAG Impuls EMUs. These trains were locking up for arbitrary reasons after being serviced at third-party workshops. The manufacturer argued that this was because of malpractice by these workshops, and that they should be serviced by them instead of third parties.

    • 50gp
      link
      fedilink
      187 months ago

      the idiots who engineered the killswitch and didnt whistleblow should get some too

      • @[email protected]
        link
        fedilink
        English
        127 months ago

        Yes, the people who committed sabotage should be arrested and forced to testify against their superiors who planned and ordered sabotage.